Patch first › Rockwell Automation
CVE-2021-22681
Rockwell Automation Logix (PLCs, Studio 5000) · Industrial and building systems
Rockwell Multiple Products Insufficient Protected Credentials Vulnerability
Score from the NVD. Collected Oct 13, 2026.
- Exploited sinceKEV catalogThe official list, kept by the US cybersecurity agency (CISA), of vulnerabilities that attackers are observed exploiting. A vulnerability only enters it with evidence.
- March 5, 2026
- RansomwareRansomwareAccording to CISA, ransomware groups (which encrypt data for ransom) use this vulnerability.
- None known
- CISA deadlineCISA deadlineThe remediation deadline set for US federal agencies. It does not apply elsewhere, but it is a good sense of urgency.
- 21 days
- CERT-FR alertCERT-FR alertCERT-FR, the incident response center of France’s ANSSI, issues an alert when a vulnerability is exploited at scale or targets France. “Active”: the alert is not closed.
- None
At a glance
Affected product: Rockwell Automation Logix (PLCs, Studio 5000) (category Industrial and building systems, indicative classification). Name in CISA’s catalog: Rockwell Multiple Products.
What should I do?
Apply the patches or mitigations from Rockwell Automation; if none are available, stop using the product. For cloud services, follow the guidance from Rockwell Automation.
Deadline set by CISA for US federal agencies: 21 days (due March 26, 2026). It only binds those agencies, but it is a useful measure of urgency.
- The vendor’s specific advisory is listed in the NVD references: CVE-2021-22681 on the NVD website.
Original text of the required action (CISA)
Apply mitigations per vendor instructions, follow applicable BOD 22-01 guidance for cloud services, or discontinue use of the product if mitigations are unavailable.
Timeline
- Vulnerability published Publication date (NVD)
- Exploitation confirmed Added to CISA’s KEV catalog
- CISA deadline Remediation deadline set for US federal agencies
The facts, with their sources
Each value with its source and collection date. Open for details.
- Exploitation confirmed
- Yes, on March 5, 2026 Date added to the catalog of exploited vulnerabilities. Exploitation itself may have started earlier. Source: KEV catalog, collected October 13, 2026 at 06:31 UTC
- Ransomware
- No known use to date That does not guarantee it is not being used: the information is not public. Source: KEV catalog, collected October 13, 2026 at 06:31 UTC
- Hunt for compromise
- Not requested by CISA Source: KEV catalog, collected October 13, 2026 at 06:31 UTC
- CISA required action
- Apply the patches or mitigations from Rockwell Automation; if none are available, stop using the product. For cloud services, follow the guidance from Rockwell Automation. Rewritten by this site from CISA’s original text. Source: KEV catalog, collected October 13, 2026 at 06:31 UTC
- CISA deadline
- March 26, 2026, 21 days Set for US federal agencies: a measure of urgency, not an obligation elsewhere. Source: KEV catalog, collected October 13, 2026 at 06:31 UTC
- Vulnerability published
- March 3, 2021 Source: National Vulnerability Database (NVD), collected October 13, 2026 at 06:36 UTC
- Product according to CISA
- Rockwell Multiple Products Filed by this site under “Industrial and building systems” (indicative classification). Source: KEV catalog, collected October 13, 2026 at 06:31 UTC
- CVSS vector
- CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H Technical detail of the score: attack vector, complexity, impact. Source: National Vulnerability Database (NVD), collected October 13, 2026 at 06:36 UTC
Description
Rockwell Automation Studio 5000 Logix Designer Versions 21 and later, and RSLogix 5000 Versions 16 through 20 use a key to verify Logix controllers are communicating with Rockwell Automation CompactLogix 1768, 1769, 5370, 5380, 5480: ControlLogix 5550, 5560, 5570, 5580; DriveLogix 5560, 5730, 1794-L34; Compact GuardLogix 5370, 5380; GuardLogix 5570, 5580; SoftLogix 5800. Rockwell Automation Studio 5000 Logix Designer Versions 21 and later and RSLogix 5000: Versions 16 through 20 are vulnerable because an unauthenticated attacker could bypass this verification mechanism and authenticate with Rockwell Automation CompactLogix 1768, 1769, 5370, 5380, 5480: ControlLogix 5550, 5560, 5570, 5580; DriveLogix 5560, 5730, 1794-L34; Compact GuardLogix 5370, 5380; GuardLogix 5570, 5580; SoftLogix 5800.
Official description from the NVD, collected Oct 13, 2026. CVE® description © The MITRE Corporation.
Multiple Rockwell products contain an insufficient protected credentials vulnerability. Studio 5000 Logix Designer software may allow a key to be discovered. This key is used to verify Logix controllers are communicating with Rockwell Automation design software. If successfully exploited, this vulnerability could allow an unauthorized application to connect with Logix controllers. To leverage this vulnerability, an unauthorized user would require network access to the controller.
Summary from CISA (KEV catalog).
CERT-FR advisories
No advisory among the latest CERT-FR publications this site follows. That does not mean there are none.
Information reused under the Open Licence 2.0 (Etalab); the date of last update is shown for each advisory. This site is neither affiliated with nor endorsed by ANSSI.
Sources for this page
- CISA KEV catalog: exploitation, date added, required action, deadline, ransomware.
- NVD (NIST): CVSS severity, publication date, description, vendor references.
- CERT-FR: advisories and alerts (in French).
- Brand and category: indicative classification by this site (method).