Skip to content
English

Patch first › Rockwell Automation

Exploited CVE from 2021, added in 2026

CVE-2021-22681

Rockwell Automation Logix (PLCs, Studio 5000) · Industrial and building systems

Rockwell Multiple Products Insufficient Protected Credentials Vulnerability

At a glance

Exploited. Added to CISA’s catalog of exploited vulnerabilities on March 5, 2026.

Affected product: Rockwell Automation Logix (PLCs, Studio 5000) (category Industrial and building systems, indicative classification). Name in CISA’s catalog: Rockwell Multiple Products.

What should I do?

Apply the patches or mitigations from Rockwell Automation; if none are available, stop using the product. For cloud services, follow the guidance from Rockwell Automation.

Deadline set by CISA for US federal agencies: 21 days (due March 26, 2026). It only binds those agencies, but it is a useful measure of urgency.

Original text of the required action (CISA)

Apply mitigations per vendor instructions, follow applicable BOD 22-01 guidance for cloud services, or discontinue use of the product if mitigations are unavailable.

Timeline

  1. Vulnerability published Publication date (NVD)
  2. Exploitation confirmed Added to CISA’s KEV catalog
  3. CISA deadline Remediation deadline set for US federal agencies

The facts, with their sources

Exploitation confirmed
Yes, on March 5, 2026 Date added to the catalog of exploited vulnerabilities. Exploitation itself may have started earlier. Source: KEV catalog, collected September 29, 2026 at 14:57 UTC
Ransomware
No known use to date That does not guarantee it is not being used: the information is not public. Source: KEV catalog, collected September 29, 2026 at 14:57 UTC
Hunt for compromise
Not requested by CISA Source: KEV catalog, collected September 29, 2026 at 14:57 UTC
CISA required action
Apply the patches or mitigations from Rockwell Automation; if none are available, stop using the product. For cloud services, follow the guidance from Rockwell Automation. Rewritten by this site from CISA’s original text. Source: KEV catalog, collected September 29, 2026 at 14:57 UTC
CISA deadline
March 26, 2026, 21 days Set for US federal agencies: a measure of urgency, not an obligation elsewhere. Source: KEV catalog, collected September 29, 2026 at 14:57 UTC
Vulnerability published
March 3, 2021 Source: National Vulnerability Database (NVD), collected September 29, 2026 at 15:00 UTC
Product according to CISA
Rockwell Multiple Products Filed by this site under “Industrial and building systems” (indicative classification). Source: KEV catalog, collected September 29, 2026 at 14:57 UTC
CVSS vector
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H Technical detail of the score: attack vector, complexity, impact. Source: National Vulnerability Database (NVD), collected September 29, 2026 at 15:00 UTC

Severity and activity

9.8 / 10 CVSS severity: critical

Score from the NVD. Collected Sep 29, 2026.

— Probability of exploitation in the next 30 days (EPSS)

FIRST’s EPSS model. Since exploitation is already confirmed, this figure is mostly useful to compare activity. Collected Sep 29, 2026.

Description

Rockwell Automation Studio 5000 Logix Designer Versions 21 and later, and RSLogix 5000 Versions 16 through 20 use a key to verify Logix controllers are communicating with Rockwell Automation CompactLogix 1768, 1769, 5370, 5380, 5480: ControlLogix 5550, 5560, 5570, 5580; DriveLogix 5560, 5730, 1794-L34; Compact GuardLogix 5370, 5380; GuardLogix 5570, 5580; SoftLogix 5800. Rockwell Automation Studio 5000 Logix Designer Versions 21 and later and RSLogix 5000: Versions 16 through 20 are vulnerable because an unauthenticated attacker could bypass this verification mechanism and authenticate with Rockwell Automation CompactLogix 1768, 1769, 5370, 5380, 5480: ControlLogix 5550, 5560, 5570, 5580; DriveLogix 5560, 5730, 1794-L34; Compact GuardLogix 5370, 5380; GuardLogix 5570, 5580; SoftLogix 5800.

Official description from the NVD, collected Sep 29, 2026. CVE® description © The MITRE Corporation.

Multiple Rockwell products contain an insufficient protected credentials vulnerability. Studio 5000 Logix Designer software may allow a key to be discovered. This key is used to verify Logix controllers are communicating with Rockwell Automation design software. If successfully exploited, this vulnerability could allow an unauthorized application to connect with Logix controllers. To leverage this vulnerability, an unauthorized user would require network access to the controller.

Summary from CISA (KEV catalog).

CERT-FR advisories

No advisory among the latest CERT-FR publications this site follows. That does not mean there are none.

Information reused under the Open Licence 2.0 (Etalab); the date of last update is shown for each advisory. This site is neither affiliated with nor endorsed by ANSSI.

Sources for this page

  • CISA KEV catalog: exploitation, date added, required action, deadline, ransomware.
  • NVD (NIST): CVSS severity, publication date, description, vendor references.
  • EPSS (FIRST): probability of exploitation.
  • CERT-FR: advisories and alerts (in French).
  • Brand and category: indicative classification by this site (method).